NO
the specific batch test not yet as per ASME Sec-II part C.
only WPS qualified on -52°C
Thanks & Regards
Sangramkeshari Routaray
Sangramkeshari Routaray
MOB NO. +91-8249921885
On Monday, 17 January, 2022, 03:22:55 pm IST, Vishwas Keskar <vvkeskar123@gmail.com> wrote:
Is this specific batch is tested and certified as per ASME.SEC II Part C for Impact testing at - 52 Deg C ?
On Mon, 17 Jan 2022, 15:02 'sangram routray' via Materials & Welding, <materials-welding@googlegroups.com> wrote:
--Dear Experts,code of construction ASME B31.3we have a qualified PQR & WPS with impact test @ -52°C , with use a specific filler wire batch. In witch filler wire MTC; manufacture recommended the impact value @ -40°C.Job's Impact requirement is -52°C.
shall I use the same specific batch Filler wire for the job?? (Y/N)or required batch test qualification (all weld test )Answer with code's justification.welding code ASME Sec-IX
Thanks & Regards
Sangramkeshari RoutarayMOB NO. +91-8249921885
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/215105493.712317.1642408446087%40mail.yahoo.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADder3N5Tc9BbcRpC8Vw_gmBeq%2BGRCDQjWxzZGBmfB6nNL9sVg%40mail.gmail.com.
No comments:
Post a Comment