Sunday, May 8, 2011

[MW:10997] Re: 10934] AWS D1.1 WPS M.no changes requiring requalification or not?

Dear All,

@ Babu & elumalai,
as from ur words,
AWS D1.1 says only on Group number.
&
In Table 4.5, PQR essential variable.
point 29) a change in base metal or combination of basemetal not
listed in pqr or qualified by table 4.8.
that means
Group number is the only essential variable here for base metal.
no other variable for basemetal.
am i right?

& G.no taable for material is not given in aws d1.1. where to refer
for that?

Regards
Srinivas


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.