Hi Andrews, The basic diffrerence between SA516 Gr.60 and SA516 Gr.60N is the plates supplied by the manufacturer with normalize.It Denotes "N". But As per ASME Section-II Part-A,Plate thickness up to 40mm shall be supplied in "As rolled Condition".More than this thickness shall be supplied with Normalizing.When notch toughness tests are required on plates of 40mm and under thickness,the plates shall be normalized unless otherwise specified by the owner. In some cases Owner may require the plates with normalize condition even if the thickness is lesser than the 40mm.In this case you have to follow the owner's requirement. Thanks & Regards, (karthik) Karthikeyan.S Getabec Energy Co.,Ltd. 379,Moo6,Soi8,Nikhomphatana, Rayong-21180, Thailand. Phone: 0066 38 897035-8 (Off) Fax: 0066 38 897034 Hand Phone: 0066 892512282 --- On Sat, 7/17/10, James cyrilandrew <jcyrilandrew@gmail.com> wrote:
|
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.