Important is rating of Pressure Gause & I think glisarine is not a issue ,glisarin may be used accordance with density so it may not be issue anyhow take suggetions from Pr.Gauge manufacturer. It is better for avoide quiry in work.
Regards,
RK Vichare
s----- Original Message -----
From: Pardeep
To: materials-welding@googlegroups.com
Sent: Wed, 13 Jul 2011 09:52:06 +0530 (IST)
Subject: [MW:11713] Can we use pressure gauge of different level of giliserene inside it
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
Regards,
RK Vichare
s----- Original Message -----
From: Pardeep
To: materials-welding@googlegroups.com
Sent: Wed, 13 Jul 2011 09:52:06 +0530 (IST)
Subject: [MW:11713] Can we use pressure gauge of different level of giliserene inside it
Dear All My query is that can we use two pressure gauges with different level of giliserene inside it in hydro test of air tank at 15bar. Pardeep Kumar
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
Comments