As per ASME Section IX – QW-403.5:
No, a change from one Group Number to another Group Number within the same P-Number shall be considered an essential variable and requires requalification of the WPS.
On Mon, 15 Dec 2025, 16:29 Alex Kumar Antony, <alexkantony@gmail.com> wrote:
Can we use Duplex WPS for Super Duplex, kindly quote with the help of codeThanks--