It's acceptable to use. Range of qualifications as be the deposited need to follow. There is no issues as long as you follow the WPS thickness requirements and deposited weld metal requirements.
On Fri, 22 Aug 2025, 11:05 am Elavarasan Mech, <elavarasan1861994@gmail.com> wrote:
Dear allPlease clarify belowWe have qualified WPS range ( 7.62 to 15.24) with impact ( pipe 3 inch sch80 )Material grade A333 gr6 +A350 LF2For WQT we select 2 inch pipe A106 Gr B wall thickness 10 mm( maximum deposited thickness 20 mm) as per ASME sec IX it's acceptable or not .please confirm the selection of WQT material and thickness rangeRegardsELAVARASAN--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAJ9L4yn5iJ1Er5xjnAgeVBVioi6djNBjwBTkN3vLp1fm%3DmKjNA%40mail.gmail.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAJ90KGSpsmJ8kPw4uV_5zVGZOeE0sic_0DO5kmAo3M_7AsmWKA%40mail.gmail.com.