Re: [MW:35750] QW-424.2, clarification

Use the PQR if:

The PQR includes Inconel 625 overlay testing (chemical composition, corrosion resistance) on P1.

The job's weld is primarily between Inconel 625 overlays.

All essential variables (welding process, thickness, etc.) are within the PQR's qualified range.

You confirm compliance with the project's code and client requirements.

 

Do not use the PQR if:

The job involves significant base metal welding (P1-to-P1) beyond the overlay, as QW-424.2 may not apply.

The PQR lacks overlay-specific tests or data for Inconel 625.

The project requires a P1-to-P1 PQR.

 

Final Guidance

Draft the WPS: Base it on the PQR, ensuring compliance with QW-424.2 and job requirements.

Consider a New PQR: If the PQR doesn't meet all conditions or project requirements, qualify a new PQR for 

P1 + Inconel 625 to P1 + Inconel 625 to ensure compliance.


C Sridhar.


On Sat, 2 Aug 2025 at 15:41, 'Birupakhya Sahu' via Materials & Welding <materials-welding@googlegroups.com> wrote:

QW-424.2

For welds joining base metals to weld metal buildup or corrosion-resistant weld metal overlay, the buildup or overlay portion of the joint may be substituted

in the test coupon by any P-Number base material that nominally matches the chemical analysis of the buildup or overlay.

With respect to the above clause, Can we approve the following condition.

PQR : P1+ inconel 625 WOL(PWHT) TO P43

Job : P1+Inconel 625 to P1+Inconel 625

Can we use this PQR to weld the Job preparing a WPS accordingly.

Can any one suggest please.

 

Regards

Birupakhya




________________________________________________________________________________________________________________________________
This email may contain confidential and/or privileged information. If you are not the intended recipient (or have received this email in error) please notify the sender immediately and destroy this email. Any unauthorized copying, disclosure or distribution of the information in this email is strictly forbidden.
________________________________________________________________________________________________________________________________

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/15608E81BA54485586DF9090A788C14E%40temaindia.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAHo%3DYihnsdsA47k39Cf8MvfxST76tAhmHu0s634baBsAV74rwA%40mail.gmail.com.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...