Below here is major factors:
1. Mixture of Shielding gases (Or + N).
2. Cold Pass Techniques (second pass should be lesser heat input from root pass approximately 75% ).
3. Control heat input with normal root penetration and excess weld-metal.
  4. Filler wire with minimum diameter to reduce heat input.


Muhammad Babur Khan
Sr. Welding Inspector 
(CSWIP 3.2.2)
Sent from my iPhone

On 19 Sep 2022, at 9:33 AM, ahmad elsharkawy <ahmad.sharkawy88@gmail.com> wrote:

No comments:

[MW:35614] Re: SS FILLER

dear , pl check A number and Gas composition use for ss cant be sutibale same % for duplex., u need to qualified with aditional testing of f...