Dear Experts,
Greetings!!
Anyone knows the reason for very low impact test values on the weld centerline.
Thanks in advance.
Welding Process : FCAWMaterial : SA 516 Gr.70 N, 20 mm ThicknessPWHT : 610 ° C ± 10° C, @ 120 MinutesTensile, Bend, Macro & Hardness Values are Accepted.But in the Charpy Impact Test @ -28° C , Average on WCL is 09 JouleIn HAZ the average is 217 Joule.Filler Wire DetailsK-71T1-C1, AWS A5.20, 1.2 mm DiameterImpact Values (as per MTC) , Charpy V-Notch @ -20° C, Avg. 54 J & Min. 27 JThank You & RegardsWilliams P Wilson+968-94600828QA/QC EngineerPlease consider the environment before printing this message
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHBxnQ56G%3Djygx%3D3qHSUNM_DP73okXanYu4JhYwfJkyM12Y2bQ%40mail.gmail.com.