Monday, September 5, 2022

Re: [MW:33432] Groove Weld Diameter- Minimum range

Hai,

Diameter restriction not applicable for WPS.
QW-452.3 Applicable for WQT only.

Regards,
Manikandan 

On Mon, Sep 5, 2022 at 11:21 AM Ponnikumar <k.ponni1994@gmail.com> wrote:
Dear experts,
kindly refer to the attached images for groove joints 2'' sch 80 ( 5.54 mm) qualified thickness and diameter as per PQR. For my query regarding this WPS image 1 is minimum dia for the groove joint is 3/4"  (25mm) as per ASME SEC IX Table QW-452.3, but the attached image WPS mentioned all sizes for diameter. 

please advise

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAKL%3DdYy%3Dn4rH8FKvd4LYjw%2BBQT0kqvb9Y1xuFLUmj6EgXYNyNw%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAPdGVmPp4%3D-XDn9Y4NBjhX_3zQbmcS0_zwgJi-L-bfGUVCf1Lg%40mail.gmail.com.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...