In our recent project i encounter one problem.
-- Material Grade : SA-516 Gr.70 Supply condition : Normalized
Dished end : Ellipsodial
Thickness : 45 mm
Forming process : Cold forming
Dished end have one cordal seam
Impact required at : -46 deg. C
so during cold forming vendor need one intermediate normalizing. and as per client requirement one more normalizing performed after complete dished end forming. So, total 2 time normalizing have to perform.
So, my question is ;
(1) During plate order i have to take 2 normalizing cycle simulation ? Yes Or No? With Reason
(2) May I take benefit of Clause UCS-85 (i) of ASME sec-8 Div.1?
(3) Is same clause applicable for welding?
(4) And If i will perform double normalizing then I have to simply double the normalizing time or 2 separate normalizing i have to perform?
(5) What will be effect on weld and base material after 2 time Normalizing?
(6) if any one encountered such issues . please help to solve
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/f9744a58-4c34-4c96-93f8-ff304e519db5%40googlegroups.com.