Sunday, January 14, 2018

Re: [MW:27256] Aluminum welding 6061-T6 mechanical test bend failure

Go for pwht first solutinizing bring material to T4 condition then artificial agening to meet T6 condition for entire structure

After welding weld haz & parent metal all should be in same ageging condition to reduce craking

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:35614] Re: SS FILLER

dear , pl check A number and Gas composition use for ss cant be sutibale same % for duplex., u need to qualified with aditional testing of f...