Friday, June 20, 2008

[MW:875] Diffusible H2 content and Hydrogen cracking study


Here we need to consider a point is that basically these Cr-Mo steels
are used for high temperature applications along with creep
resistance. Therefore ,selection of welding consumbales are also
important and the responsibility of welding engineer with respect to
Strength,Chemical Composition,Service condition and application etc..
Hence, carbon steel electorde E6013 is not appropriate for welding cr-
mo steels beacause of above said reasons..

--
Regards

Vasanth
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35507] WPS for Furnace PWHT

As per ASME B31.3, Clause 331.1.6 (b): Any required PWHT shall be carried out in accordance with the qualified WPS. For furnace PWHT inv...