Tuesday, May 17, 2011

Re: [MW:11071] Hold points & Witness Points

Hi MPK
 
cannot answer in one word,
 
HOLD POINT - WITNESSING OF INSPECTION ACTIVITY IS MANDATORY, ACTIVITIY MUST BE WITNESSED, YOU CANNOT PROCEED TO NEXT ACTIVITY UNTIL INPECTION IS CLEARED. YOU HAVE TO NOTIFY CLIENT AND MUST WAIT UNTIL THEY COME AND WITNESS
 
WITNESS POINT - WITNESSING OF INSPECTION ACTIVITY IS MANDATORY UNLESS AND UNTILL EXEMPTED BY CLIENT IN WRITTING. YOU HAVE TO NOTIFY THE CLIENT, CLIENT MAY WITNESS OR MAY NOT WITNESS, BUT YOU NEED WRITTEN STATEMENT IF CLIENT DO NOT WANT TO ATTEND THE INSPECITON.
 
 
 
 
 
On Tue, May 17, 2011 at 1:43 PM, mpk mpk <ranmi2007@gmail.com> wrote:
Dear Experts,
 
Any body Explain for Hold points and witness points. bcoz i need single line answers...
 
Thank you,
 
MPK..

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:34916] Applicability of Impact requirement as per ASME B31.3

Dear All, Design code – ASME B31.3, Welding Code- ASME BPVC SEC IX Material  to be used used during Fabrication - SA 333Gr6 (P No.1 G...