As per ASME Section IX, welder qualification for a dissimilar weld (P5A → P8) performed using F-No. 43 filler cannot be done on
P5A → P5A materials alone. The test coupon must include at least one P8 base metal to represent the metallurgical condition of
the production weld. Therefore WQT must be performed on a CS + SS test coupon. CS + CS coupon with F43 is not acceptable under
ASME IX.
Sridhar.
On Tue, 3 Feb 2026 at 13:20, Aslam Khan <akchillu@gmail.com> wrote:
I have scenario in site, we have to qualify welders for cs to ss,but we dont have ss material available ,can we do with cs alone using f43 filler wire. wps- p5a to p8- f.no-43Wqt - p5a to p5a- f.no-43--Thanks®ards
Aslam
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAA7Erp%3DnRb20byLE0w2M14GDcFF3G1wkuy-5FzsTxyCpp7Q0Tw%40mail.gmail.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAHo%3DYii0p7DJTBeeOVB9zdjhWGu%3DpVtVLzmVxXP6tXB02rmZWw%40mail.gmail.com.
Comments