Friday, February 23, 2024

[MW:34755] Re: A 333 Gr.6 toughness test

no, replace the pipe.

On Saturday, December 30, 2023 at 2:40:52 PM UTC+3 dia shukr wrote:
Hi friends

I have pipe A333 Gr,6 with design minimum temperature (-10C).Will I need to do a toughness test??As you know, depending on table A-1 in ASME B31.3 the minimum temperature is (-50C).

Thanks every one

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/87aef01c-241f-4484-a4ea-7422abf8fb47n%40googlegroups.com.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...