Kindly advice the requirement of impact test for Reinforcing pad plate which is welded to the main header. Kindly note that the main header pipe is already impact tested.
Service: Non Sour
Lateral Material: SS316/316L
Lateral Sizes:
60" X 30"
60" X 42" and
60" X 52"
Code: ASME B31.3
Thanks in advance.