[MW:34386] Re: WPS FOR 321H

Dear Ashish 

What is service of the equipment ?(Operating temperature ?)?

The ER321  is compatible wire .

for TYP 347/321 base metals -ER 16 8 2 is deployed when the weld need less FN   when operating temperatures  are higher (> 500 Deg C ) 

Thanks 

Vishwas - IWE
International Welding Engineer 


On Wednesday, July 5, 2023 at 9:02:37 PM UTC+5:30 Ashish Chacko wrote:
Dear experts , can anyone share me the wps for 321H.Am getting confused for the selection of filler material, ER347 or ER 16-8-2.Please support .

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4f57b14d-e290-4691-a5e8-92f4a0009aean%40googlegroups.com.