What is service of the equipment ?(Operating temperature ?)?
The ER321 is compatible wire .
for TYP 347/321 base metals -ER 16 8 2 is deployed when the weld need less FN when operating temperatures are higher (> 500 Deg C )
Thanks
Vishwas - IWE
International Welding Engineer
On Wednesday, July 5, 2023 at 9:02:37 PM UTC+5:30 Ashish Chacko wrote:
Dear experts , can anyone share me the wps for 321H.Am getting confused for the selection of filler material, ER347 or ER 16-8-2.Please support .