Skip to main content

Re: [MW:32119] Sulfuric acid drum nozzle problem

Dear sir,

Greetings 

kindly  make sure that the pipe thickness is not thinned using DIGITAL RT if possible.  

We experienced the same problem in repair of sulphuric acid vertical mounted vessel , Carbon steel A 516  Gr B , nozzle failure . 

later we found under deposit corrosion of nozzle pipes . the we back gouged and flush grounded with E-316 for repair. 

please update , if you got better solution. 



Regards

Vinoth kanna
QC- welding & piping inspector 
Manifa Project

API -510, CSWIP 3.1, NDT level II - UT, RT ,PT, MT, VT,LT,Infrared & Thermography 
Technical - Metallurgy

Contact : M - +91-9787954338,+966-539127946
              Email id : srvkanna1@gmail.com


On Tue, Mar 30, 2021 at 2:01 PM okay Tutar <okaytutar@gmail.com> wrote:
Hello everyone, I hope you all have a nıce day.

We had a problem in sulfuric acid %99 conct. drum nozzle.

After 2 years of operation, suddenly our nozzle has been failured.
We checked api 571.Concentration of acid is ok, it is %99.Speed of acid is lower than critical level.
But, when we examine flange and piping of nozzle. There is general corrosion and thickness of weld neck is thinned . Our material is carbon steel. But, in pipe thickness is not thinned.
Do you have suggestion for reason of this problem ? What could it be ?

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/d4b67686-33e7-429b-9ebc-9e16768ddb8cn%40googlegroups.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADbO-YYpHFv_s2YAn7dg7jddS52%3DGx5%3DvObcya55hO1LTBhJAg%40mail.gmail.com.

Comments

Popular posts from this blog

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

[MW:5202] RE: 5200] NDT after PWHT

------------------------------------- Interpretation:  I‑89‑14 Subject:         Section I (1986 Edition, 1987 Addenda), PW‑11,                  NDE Prior to PWHT Date Issued:     December 15, 1988 File:            BC88‑393   Question: Does PW‑11 require that NDE be performed on welds after they have been subjected to the postweld heat treatment required by PW‑39?   Reply: No, unless the conditions described in PW‑11.2.2 exist. ---------------------------------------------- Interpretation:  VIII-1-98-09 Subject:         Section VIII, Division 1 (1995 Edition, 1996 Addenda); NDE                 ...

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...