Thursday, September 15, 2016

[MW:25400] Welding of UNS S 31254


Can anyone suggest correct tig filler wire for welding of
A 182 F44 : UNS NO. S 31254

Please suggest only TIG welding consumable classified in ASME SEC  II C.

Unlisted filler wires are not acceptable to  client which is a long procedure.

Job thickness is less than 10mm.

Design temp is 85 degree Celsius

Code of construction is ASME B31.3


Regards

Prem Nautiyal 


Sent from my Samsung Galaxy smartphone.

No comments:

Re: [MW:35686] HDPE WPS

Refer ASME SEC IX  There is separate chapter for Plastic welding . Based on that you have to prepare  Sent from my iPhone On 21 Jun 2025, at...