Re: [MW:35967] WPS requalification for repair weld ASME B31.3

 ASME B31.3 refers ASME Sec.IX for WPS/PQR qualification. PWHT Soak time after Repair will be considered during original PQR qualification and when Charpy Impact tests are required, below snap shot of ASME Sec.IX applies. Normally in Pipe Mill, MPQ (Manufacturer Procedure Qualification) with welding & Heat Treatment will be performed including repair PWHT cycles during pipe production. Thanks & Regards J.Gerald Jayakumar 0091-8838619635 On Thursday, 29 January 2026 at 08:52:28 am IST, Babur Khan <mbabur.bwp@gmail.com> wrote: Greetings, Thank you for your kind response. In pur PQR, soaking time for repairs Welding not considered.  Muhammad Babur Khan Sent from my iPhone On 28 Jan 2026, at 8:48 AM, 'james gerald' via Materials & Welding ...

[MW:35968] Heat In Put Calculation for Impact Tested WPS (ASME Sec. IX)

Hello, Dear Expert, I would appreciate your insights on the following question concerning heat input calculations for impact-tested WPS. The Qualification Code is ASME Sec. IX. Yes, there is an impact test. The contractor has submitted the WPS heat input, which is shown in the screenshot below. (The second last and last columns were added by me. Question: How do you calculate heat input? 1. Third Last Column: The contractor recorded the highest heat input from PQR on the WPS as it is. 2. Second Last Column: Heat input is computed by averaging the amperage, voltage, and travel speed. 3. Last Column: The calculation of heat input relies on the maximum amperage, voltage, and travel speed. Which method is the correct one for calculating heat input? Heat Input will be higher than from PQR with available variables.  Reference :  Table QW-253 Welding Variables Procedure Specifications (WPS) — Shielded Metal-Arc Welding (SMAW) QW-409.1 Increase in heat input shall be consdire essential variabl...

Re: [MW:35969] Heat In Put Calculation for Impact Tested WPS (ASME Sec. IX)

Hi, There are some noticeable portions in your below table for Heat Input. 1. Your contractor has provided average Heat Input but according to ASME Sec.IX , it is the maximum Heat Input. 2. In your Cap pass, Heat Input is very High since for cap pass you use 2.5mm electrode and the Travel speed will be relatively faster and the allowable Current ranges for 2.5mm electrodes as provided welding consumable manufacturer may not be in this limit. For GTAW & SMAW  process, the code ASME Sec,IX provides the below formula. Ways for representation of  Heat Input for each Pass (RooT, Hot/cold, Fill & Cap passes). You can use a Portable arc monitor (PAM) unit to measure Heat Input or use Tong tester for measuring Current & voltage and stop watch to measure Travel Speed. When charpy tests are required Heat Input is a supplementary essential variable. Way 1 As per ASME Sec,IX, you can mention only the maximum limit of the Heat Input for ach pass no minimum limit applies. Way2...

[MW:35970] Bolt torquing Procedure

Dear Team, Does anyone have a bolt torquing procedure? Please share.   Thanks & Best Regards Saleem manhappulath Mob:+966533595849 WhatsApp:+919526445936 -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAMSLg-6XE%3DVWXHcBd3jdiziRwyhjswr0QFTNtx1P4bvM%2BjLs3w%40mail.gmail.com .

[MW:35971] FCAW FILLER WIRE FOR S460M/ ASTM A572 GR 65

Dear All, Please kindly advise which FCAW, SMAW filler wire/electrode need for welding of S460M -- Thanks & Regards Mohammed Tajuddin WELDING INSPECTOR CSWIP 3.1 Contact  0530833486 JUBAIL -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CACZrEUaJAsEZ-Mq3SDeNgU%2BesORe7zdou_Ewgi11L6gTF8ZUnQ%40mail.gmail.com .

Re: [MW:35972] FCAW FILLER WIRE FOR S460M/ ASTM A572 GR 65

Dear Mr. Thajuddhin we can use  E81T1-Ni1 for FCAW and  E8018-G for SMAW  Thanks & Best Regards Saleem manhappulath Mob:+966533595849 WhatsApp:+919526445936 On Mon, Feb 2, 2026 at 9:24 AM Tajuddin Mohammed < tajuddinjntu@gmail.com > wrote: Dear All, Please kindly advise which FCAW, SMAW filler wire/electrode need for welding of S460M -- Thanks & Regards Mohammed Tajuddin WELDING INSPECTOR CSWIP 3.1 Contact  0530833486 JUBAIL -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CACZrEUaJAsEZ-Mq3SDeNgU%2BesORe7zdou_Ewgi11L6gTF8ZUnQ%40mail.gmail.com . -- https://materials-welding....

Re: [MW:35973] Bolt torquing Procedure

On Mon, Feb 2, 2026 at 11:33 AM Tajuddin Mohammed < tajuddinjntu@gmail.com > wrote: Bolt torquing procedure for Structural steel or piping/pipeline? On Mon, Feb 2, 2026 at 9:09 AM Saleem Manhappulath < manhappulathsaleem@gmail.com > wrote: Dear Team, Does anyone have a bolt torquing procedure? Please share.   Thanks & Best Regards Saleem manhappulath Mob:+966533595849 WhatsApp:+919526445936 -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAMSLg-6XE%3DVWXHcBd3jdiziRwyhjswr0QFTNtx1P4bvM%2BjLs3w%40mail.gmail.com . -- Thanks & Regards Mohammed Tajuddin WELDING INSPECTOR CSWIP 3.1 Cont...

Re: [MW:35973] Bolt torquing Procedure

Please find the attached On Mon, Feb 2, 2026 at 9:09 AM Saleem Manhappulath < manhappulathsaleem@gmail.com > wrote: Dear Team, Does anyone have a bolt torquing procedure? Please share.   Thanks & Best Regards Saleem manhappulath Mob:+966533595849 WhatsApp:+919526445936 -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAMSLg-6XE%3DVWXHcBd3jdiziRwyhjswr0QFTNtx1P4bvM%2BjLs3w%40mail.gmail.com . -- Thanks & Regards Mohammed Tajuddin WELDING INSPECTOR CSWIP 3.1 Contact  0530833486 JUBAIL -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You r...

Re: [MW:35976] FCAW FILLER WIRE FOR S460M/ ASTM A572 GR 65

SMAW  -  E8018C1           SFA-5.5 FCAW   -  E81T1-Ni1        SFA-5.28 Thanks & Regards J.Gerald Jayakumar 0091-8838619635 On Monday, 2 February 2026 at 11:54:59 am IST, Tajuddin Mohammed <tajuddinjntu@gmail.com> wrote: Dear All, Please kindly advise which FCAW, SMAW filler wire/electrode need for welding of S460M -- Thanks & Regards Mohammed Tajuddin WELDING INSPECTOR CSWIP 3.1 Contact  0530833486 JUBAIL -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from ...

Re: [MW:35977] FCAW FILLER WIRE FOR S460M/ ASTM A572 GR 65

Sorry try SMAW  E8018C3 Thanks & Regards J.Gerald Jayakumar 0091-8838619635 On Monday, 2 February 2026 at 03:17:41 pm IST, 'james gerald' via Materials & Welding <materials-welding@googlegroups.com> wrote: SMAW  -  E8018C1           SFA-5.5 FCAW   -  E81T1-Ni1        SFA-5.28 Thanks & Regards J.Gerald Jayakumar 0091-8838619635 On Monday, 2 February 2026 at 11:54:59 am IST, Tajuddin Mohammed <tajuddinjntu@gmail.com> wrote: Dear All, Please kind...

Re: [MW:35978] Duplex WPS for Super Duplex

DSS and SDSS are same group no. as per ASME IX. i.e. P10H G1 On Monday, December 15, 2025 at 10:05:44 PM UTC+5:30 syed kauser ahmed wrote: As per ASME Section IX – QW-403.5: No, a change from one Group Number to another Group Number within the same P-Number shall be considered an essential variable and requires requalification of the WPS. On Mon, 15 Dec 2025, 16:29 Alex Kumar Antony, < alexk...@gmail.com > wrote: Can we use Duplex WPS for Super Duplex, kindly quote with the help of code Thanks -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-weld...@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/ee5dcbf4-b6cb-4421-8338-04e109d45b15n%40googlegroups.com . -...

Re: [MW:35978] Bolt torquing Procedure

Sample is attached. Regards, Saleem Manhappulath < manhappulathsaleem@gmail.com >, 2 Åžub 2026 Pzt, 09:09 tarihinde ÅŸunu yazdı: Dear Team, Does anyone have a bolt torquing procedure? Please share.   Thanks & Best Regards Saleem manhappulath Mob:+966533595849 WhatsApp:+919526445936 -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAMSLg-6XE%3DVWXHcBd3jdiziRwyhjswr0QFTNtx1P4bvM%2BjLs3w%40mail.gmail.com . -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials ...

Re: [MW:35980] Duplex WPS for Super Duplex

Super Duplex have a Tensile strength of 115ksi whereas duplex have a Tensile strength of 95 ksi. You cannot use a duplex PQR to weld super duplex SS though P.No/F.No/A.No(if used super duplex) are same but additional requirements like Corrosion test restricts them Thanks & Regards J.Gerald Jayakumar 0091-8838619635 On Monday, 2 February 2026 at 04:19:32 pm IST, Mohmmed Dudhiyawala <mdudhiya007@gmail.com> wrote: DSS and SDSS are same group no. as per ASME IX. i.e. P10H G1 On Monday, December 15, 2025 at 10:05:44 PM UTC+5:30 syed kauser ahmed wrote: As per ASME Section IX – QW-403.5: No, a change from one Group Number to another Group Number within the same P-Number shall be considered an essential variable and requires requalification of the WPS. On Mon, 1...

Re: [MW:35981] Bolt torquing Procedure

Is there any separate procedure for structural steel or piping/pipelines Thanks & Best Regards Saleem manhappulath Mob:+966533595849 WhatsApp:+919526445936 On Mon, Feb 2, 2026 at 12:32 PM Tajuddin Mohammed < tajuddinjntu@gmail.com > wrote: Bolt torquing procedure for Structural steel or piping/pipeline? On Mon, Feb 2, 2026 at 9:09 AM Saleem Manhappulath < manhappulathsaleem@gmail.com > wrote: Dear Team, Does anyone have a bolt torquing procedure? Please share.   Thanks & Best Regards Saleem manhappulath Mob:+966533595849 WhatsApp:+919526445936 -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/ma...

[MW:35982] Mechanical Testing Procedure

Dear Team, Does anyone have a procedure for mechanical testing, including tensile test, bend test, Vickers hardness test, impact test, macro examination, fillet fracture test, ferrite testing, and chemical analysis ?   Thanks & Best Regards Saleem manhappulath Mob:+966533595849 WhatsApp:+919526445936 -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAMSLg-4Ew3c45rs7PkpDod4NO63AofNPnkWJwAayFKhuUocBkw%40mail.gmail.com .

[MW:35983] P5A to P8

I have scenario in site, we have to qualify welders for cs to ss,but we dont have ss material available ,can we do with cs alone using f43 filler wire. wps- p5a to p8-  f.no-43 Wqt - p5a to p5a- f.no-43 Thanks&regards Aslam  -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAA7Erp%3DnRb20byLE0w2M14GDcFF3G1wkuy-5FzsTxyCpp7Q0Tw%40mail.gmail.com .

Re: [MW:35984] P5A to P8

We can use P5a.  Sent from Outlook for Android From:  materials-welding@googlegroups.com <materials-welding@googlegroups.com> on behalf of Aslam Khan <akchillu@gmail.com> Sent:  Tuesday, February 3, 2026 10:50:27 am To:  materials-welding@googlegroups.com <materials-welding@googlegroups.com> Subject:  [MW:35983] P5A to P8 I have scenario in site, we have to qualify welders for cs to ss,but we dont have ss material available ,can we do with cs alone using f43 filler wire. wps- p5a to p8- f.no-43 Wqt - p5a to p5a- f.no-43 Thanks&regards Aslam  -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups...

Re: [MW:35985] P5A to P8

As per code you can use.  Convince your customer also before starting WQT. Thanks & Regards Manoj On Tue, 3 Feb 2026, 13:20 Aslam Khan, < akchillu@gmail.com > wrote: I have scenario in site, we have to qualify welders for cs to ss,but we dont have ss material available ,can we do with cs alone using f43 filler wire. wps- p5a to p8-  f.no-43 Wqt - p5a to p5a- f.no-43 Thanks&regards Aslam  -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAA7Erp%3DnRb20byLE0w2M14GDcFF3G1wkuy-5FzsTxyCpp7Q0Tw%40mail.gmail.com . -- https://materials-welding.blogspot.com/ https://www.linkedin.com/gro...

Re: [MW:35985] Mechanical Testing Procedure

1.  Tensile Test (ISO 4136 / ASTM E8) Purpose:      Determine yield strength, UTS, and elongation. Specimen:  Transverse or all-weld-metal, machined to standard dimensions. Procedure:   Mount the  two specimens in a calibrated tensile machine. Apply load at controlled strain rate until fracture.   Record YS, UTS, EL%. Acceptance:  Tensile ≥ minimum specified; fracture location acceptable.   2.  Bend Test (ISO 5173 / ASTM E190 / AWS B4.0 ) Purpose:       Check ductility and weld soundness. Specimen:     Face/root/side bend, edges smoothed. Procedure:   Bend to 180° around specified mandrel. Inspect tension surface. Acceptance:  No cracks > 3 mm; no open defects.   3. Vickers Hardness Test (ISO 6507 /  ASTM E92 / AWS A4.2 ) Purpose:        Evaluate hardness of WM, HAZ, BM. Specimen:     Polished transverse section; HV10 or HV5 load. Procedure:   Apply load for 10–15 s. Take impressions across the weld line.   Record hardness profile. Acceptance:  Project-specific (e.g., ≤ 250 HV10 for...