Re: [MW:20150] Hydrotest pressure criteria

Hi Parag,

Can you recall when exactly was the switch from 1.5x to 1.3x made? Which Edition or Addenda?

Best regards,
Tim


On Wednesday, May 1, 2013 6:10:17 PM UTC+8, Parag Pansare wrote:
Dear Nishant,

The pressure vessels build as per ASME Sec.VIII Div.I year1999 editions or earlier follows the hydrotest pressure of 1.5 times the MAWP.

Any vessels construction following after the 1999 editions follows the hydrotest pressure of 1.3 times the MAWP (maximum allowable working pressure).

The reason for using or changing the factor 1.5 to 1.3 is quite logical.

Suppose you are fabricating a pressure vessel of Carbon steel plate confirming to SA 516 Gr. 60 (I.e. specified minimum ultimate tensile strength of material 60,000 psi) then by applying factor of safety of 3.5 which is based on vessel constructed earlier than 1999 code you have design stresses of 60000/3.5=17,142 psi.

Now you are fabricating the vessel by following later editions I.e after1999, where the factor of safety has changed to 3.0, then in this case you have a stress value of 60000/3.0=20000 psi.

Now if your vessel design temp is 300℉ ( The Allowable stress for SA 516 Gr. 60 at 300℉=18,900 psi) now you are hydrotesting the vessel built by both the editions of the code the you have

For 1999 edition or earlier:
Hydrotest pressure =1.5*MAWP* stress at test temperature / stress at design temperature.

=1.5*MAWP* 17142 / 18900
=1.36 MAWP.

For later editions:
Hydrotest pressure =1.3*MAWP* stress at test temperature / stress at design temperature.

=1.3*MAWP* 20000 / 18900
=1.37 MAWP.

Which are almost the same.
Thus by following any edition of this pressure vessel construction code the hydrotest pressure remains the same.

I hope I have satisfied your queries / doubt.

Regards,

PARAG PANSARE.



Sent from my HTC


----- Reply message -----
From: "nishant nair" <nishan...@yahoo.com>
To: "material...@googlegroups.com" <material...@googlegroups.com>
Subject: [MW:17573] Hydrotest pressure criteria
Date: Sat, Apr 27, 2013 19:02

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...