Wednesday, December 28, 2011

[MW:13349] Oxygen level in purging gas during welding of duplex stainless steel

Hi friends,
 
I have 2 different specification which the requirements are different for the oxygen level in purging gas during the welding of super duplex pipe.
 
One of them calls for 25 ppm (0.0025%) another one calls for 5000 ppm (0.5%). Could you please shed some light on this as which one is up to the standard with references?
 
Thanks,
Martin.

No comments:

[MW:35668] Selection of Filler/Electrode.

Dear Gentlemen, Kindly advise me as we have tube to tubesheet joint. Tube moc is incoloy 800 And tubesheet moc is F53 SDSS (Super duplex sta...