Thursday, January 31, 2008

[MW:543] IGC Micro Structure Magnification

Instead of 250X magnification on the specimen, where the vendors standard suggests 50X, 100X, 200X, 500X magnification only

 

What we are going to miss when we have 200X micro instead of 250X, or is it makes sense economically to go for 500X specimens?

 

ASTM A262 Practice E suggests the range of 100 to 250X, but the contractual obligation is 250X mandatory. Please share your views


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35507] WPS for Furnace PWHT

As per ASME B31.3, Clause 331.1.6 (b): Any required PWHT shall be carried out in accordance with the qualified WPS. For furnace PWHT inv...