The joint between the cover flange and the nozzle neck is a groove joint. However, the maximum thickness qualified in the WPS (20.0 mm) does not comply with the nozzle neck thickness requirement (20.4 mm). Therefore, this WPS is not applicable to this joint.
PWHT is an essential variable, and the approved WPS must be followed. That means if a WPS qualified with PWHT is used, PWHT shall be performed in accordance with the WPS.
Và o Th 2, 15 thg 12, 2025 lúc 13:14 Shivasankar A <shivasankar2593@gmail.com> đã viết:
Hi Friends,Refer the attached image,In this, The cover flange thickness is 69.8 mm & The Nozzle thickness is 20.4 mm.the Nozzle is Set on on the Cover Flange with Full penetration Weld the groove is given on the Nozzle pipe.The Final Fillet weld Size is 15 mm.So may i use the WPS which Covers the thickness range from 1.5 to 20 mm?If not, Kindly explain why?Also Tell me the WPS Qualified with Heat treatment can be weld for the Job without Heat Treatment?Looking for your valuable Replies. Kindly Support.regards,A.Shivasankar--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/6032dcdf-efef-437b-b47a-9b89a3fa83e6n%40googlegroups.com.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAPmM69scSf0Q26gYvYOFQk9P6ZEhNuzOJXHqVpcLObF9r8%2Bw%3Dg%40mail.gmail.com.
Comments