Refer the attached image,
In this, The cover flange thickness is 69.8 mm & The Nozzle thickness is 20.4 mm.
the Nozzle is Set on on the Cover Flange with Full penetration Weld the groove is given on the Nozzle pipe.
The Final Fillet weld Size is 15 mm.
So may i use the WPS which Covers the thickness range from 1.5 to 20 mm?
If not, Kindly explain why?
Also Tell me the WPS Qualified with Heat treatment can be weld for the Job without Heat Treatment?
Looking for your valuable Replies. Kindly Support.