Re: [MW:35908] Visual examination- Any reference



Dear Mr. Pradeep,

The statement is essentially correct. It is not a present Section V requirement but, it was in the earlier editions and is still preserved through 

cross-references in other ASME sections. The controlling clause is: ASME Section V– Article 9 (T-952  or T-953, depending on the edition).

Typical wording is edition-dependent and wording shift slightly between editions, which is why you may not see the exact sentence you

quoted in your copy.

·   Viewing distance: The VT shall be conducted at a distance not greater than 24 in. (600 mm)

·   Lighting: Illumination shall be sufficient to provide a minimum of 15 foot-candles (≈160 lux) for general examination and 50 foot-candles 

    (≈540 lux) for the detection of small discontinuities.

Later editions of Section V streamlined Article 9, removing some descriptive text. The same technical requirements are now referenced 

rather than repeated. Many construction codes restate the VT requirements directly. As a result, clients often quote VT requirements from:

·  Older Section V editions

·  Construction codes (Section VIII, IX, B31, etc.)

·  Employer/Owner VT procedures derived from Article 9.

For example, ISO 17637 explicitly states:

·  Viewing distance ≤ 600 mm

·  Minimum illumination:

160   lux (~15 fc) general

500 lux (~50 fc) for fine indications

This is why many VT procedures include exactly your quoted values. 


Best way to cite it in a procedure is:

Visual examination shall be performed in accordance with ASME Section V, Article 9. Illumination and viewing conditions shall comply with 

the requirements referenced therein (minimum 15 fc for general examination; 50 fc for detection of small discontinuities, and viewing distance

not exceeding 600 mm).


Trust it is clear.

rgds,

C Sridhar.


Virus-free.www.avg.com

On Sat, 13 Dec 2025 at 11:12, s. pratheep <pratheep013@gmail.com> wrote:

Dear expert, 
please review the screenshot above. Is it correct? If so, could someone please provide a reference? Article 9 of ASME Section V does not mention this. Can anyone confirm?


With regards
Pradeep 

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAD3Y_Ug421wDr0XsOy_TPCMxX%2Be8Hdj%2BCdMRxWWuGd4_ZOqqKQ%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAHo%3DYijaW9fLo%3D%3Dr0kCzC9nP4N8imECcXqGsEQ6cW_H37aXH8A%40mail.gmail.com.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...