Monday, January 22, 2018

[MW:27274] PQR PMI - Fe value

Dear Experts 

can you advise me for the below clarifications,

We have Done the PQR as mentioned below material and after PQR the test piece measured the PMI value and all chemical composition are meet the Sec-2 C requirement except Fe value, please explain why it is happen and provide some technical data.

Base metal  - ASTM A312 TP 304L to ASTM A312 TP 304L

Electrode :  - ER NiCr-3

SFA 5.14 - Actual Fe - 3% Max  & measured value - 8.83%



Best Regards,

Mohamed Ali.




--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:35686] HDPE WPS

Refer ASME SEC IX  There is separate chapter for Plastic welding . Based on that you have to prepare  Sent from my iPhone On 21 Jun 2025, at...