Both channels are belongs to one HE.
Regards,
Manohar.
ClauseFrom: Raghuram Bathula <raghurambathula@gmail.com>
Sent: Tue, 05 Apr 2022 15:37:49
To: Materials-Welding <materials-welding@googlegroups.com>
Subject: Re: [MW:33030] channels and bonnets with six or more tube passes
it is from one end of HE to another end is consider as 1 pass (not individual channel)
On Tue, 5 Apr 2022 at 15:22, 'manohar matcha' via Materials & Welding <materials-welding@googlegroups.com> wrote:
Dear Group Members,
Please share your opinion/interpretation on API 660 Clause 9.6.9 (a)
Tube passes to be considered for individual channel or both channels (if Exchanger is having 2 channels)?
in other words:
Individual Channel passes to be considered or cumulative passes for both channels to be considered..?
Regards,
Manohar.
--
--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADxVubkQWFGHa70Wg-rztp22TzE0fmybM=5PWPP0yjm8qEAegA@mail.gmail.com.
--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/1649153269.S.14357.28649.f5-224-101.1649156519.452%40webmail.rediffmail.com.
No comments:
Post a Comment