Skip to main content

Bohler Stainless Steel Flux Cored Wires

http://www.btwusa.com/html/tips_page_2.html#AWS

Welding Procedure

Böhler flux cored wires should be operated on D.C., electrode positive, preferable with a slightly trailing torch angle (approx. 80°). Parameter settings are similar to solid wire. However, a faster wire feed rate is required.

We recommend to use shielding gases like Argon + 15-25% CO2 or 100% CO2.

A low carbon content of max.0.03% is assured with Ar/CO2 mixed gas. The gas flow rate should be 15-18 l/minute.

Torch Positioning

Recommended parameter settings

http://www.btwusa.com/assets/images/Steel_Wire_Recom_2.gif

Optimum parameter settings may vary according to actual welding conditions.

Welding can be carried out using MIG/MAG welding equipment. When using 100% CO2 rather than a gas mixture it is necessary to increase the welding voltage by 2 volts. The wire stick-out (distance between contact tip and workpiece) should be 5/8 – 1 inch (15-25 mm). Standard feed rollers with a smooth groove can be used.

Adequate fume extraction is recommended as it always should be when welding stainless steels.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...