Re: [MW:35085] Interpass Temp.

Dear,

To check the interpass temperature for a material during welding or similar processes, you can follow these steps:

Tools and Equipment Needed:

  1. Temperature Measuring Device: Typically, a contact or non-contact thermometer (e.g., infrared thermometer) or temperature-indicating crayons (Tempilstik).
  2. Protective Gear: Wear appropriate personal protective equipment (PPE) such as gloves and safety glasses.

Steps to Check Interpass Temperature:

  1. Preparation:

    • Ensure the surface is clean and free from any contaminants that might affect the temperature reading.
    • Identify the area where you will measure the temperature. Typically, this should be close to the weld zone but not directly in it.
  2. Using a Contact Thermometer:

    • Place the probe of the contact thermometer directly on the material surface.
    • Hold it in place until the temperature stabilizes and take the reading.
  3. Using a Non-Contact (Infrared) Thermometer:

    • Aim the infrared thermometer at the area where you want to measure the temperature.
    • Ensure the thermometer is at the correct distance as specified by the manufacturer for accurate readings.
    • Pull the trigger to take the temperature reading.
  4. Using Temperature-Indicating Crayons:

    • Select a crayon with a melting point close to your desired interpass temperature.
    • Mark a small area on the material with the crayon.
    • If the crayon mark melts, the material is at or above the temperature indicated by the crayon. If it does not melt, the temperature is below the crayon's melting point.

Best Practices:

  • Consistency: Measure the interpass temperature consistently at the same location to ensure accurate monitoring.
  • Accuracy: Calibrate your temperature measuring devices regularly for accurate readings.
  • Documentation: Record the temperature readings to maintain a log for quality control and compliance with welding procedures.

Tips:

  • Ensure there is good contact between the thermometer probe and the material surface for accurate readings.
  • When using an infrared thermometer, avoid measuring reflective surfaces unless you have accounted for emissivity adjustments.
  • Follow the manufacturer's instructions for using and calibrating your temperature measuring devices.

Safety Considerations:

  • Be cautious of hot surfaces to avoid burns.
  • Ensure that measuring devices are rated for the temperature range of your application.

By following these steps, you can effectively check the interpass temperature to ensure compliance with welding procedures and maintain the quality of your material.

Regards,

AB


On Sun, 23 Jun 2024 at 17:25, saleem manhappulath <saleemm9526@gmail.com> wrote:
Dear Experts,

    how to check interpass temp. for a material


thanks 
saleem

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/69a3b7f6-2385-422b-ad72-e984087eafc8n%40googlegroups.com.


--
Best regards,

Amol K.B
B.E(Mech), CSWIP 3.2.2, NACE CIP 1 & ASNT LII(4M)

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAADcG1pz0ze-x-0bX_3rBGfqg4baso7sB8dRxCjy%3DSsHdX6OPA%40mail.gmail.com.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...