Dear Mr. Pandiyan
please Mention the thickness of PQR.
Accordingly any one can say you MIN & MAX limit.
for Impact test Follow QW 403.6
Thanks & Regards
Sangramkeshari Routaray
Zeeco India,
Sangramkeshari Routaray
Zeeco India,
Cswip3.1, NDT level-II (UT,RT,MT & PT)
ISO Lead Auditor 9001:2015
MOB NO. +91-8249921885
On Monday, August 16, 2021, 09:10:38 AM GMT+5:30, Raja <krajapandiyan@gmail.com> wrote:
i have some doubts in WPS, if possible kindly clarify me
1) If PQR is done with Normalization heat treatment (PWHT done above the upper critical temperature), what is the qualified base metal thickness range to be taken ( min to max ) any special condition applicable in ASME Sec IX?
2) When Impact test is applicable to the WPS, then what is the qualified base metal thickness range to be taken ( min to max ). any special condition in ASME Sec IX?