Skip to main content

Re: [MW:20402] MANUFACTURING DEFECT IN PIPES

Good Day,
 
Please provide the applicable code refernce of your pipes purchased and photos for easy refernce.
 
 
Below refernce is from API 5L 45th Edition 

9.10.5 Geometric deviations

9.10.5.1

For other than dents, geometric deviations from the normal cylindrical contour of the pipe

(e.g. flat spots and peaks) that occur as a result of the pipe forming process or manufacturing operations

and that exceed 3,2 mm (0.125 in) in depth, measured as the gap between the extreme point of the

deviation and the prolongation of the normal contour of the pipe, shall be considered defects and shall be

treted in accordance with C.3 b) or C.3 c).

9.10.5.2For dents, the length in any direction shall be 0,5 D and the depth, measured as the gap

between the extreme point of the dent and the prolongation of the normal contour of the pipe, shall not

exceed the following:

a) 3,2 mm (0.125 in) for cold-formed dents with sharp-bottom gouges;

b) 6,4 mm (0.250 in) for other dents.

Dents that exceed the specified limits shall be considered defects and shall be treated in accordance with

C.3 b) or C.3 c).

9.10.6 Hard spots

Any hard spot larger than 50 mm (2.0 in) in any direction shall be classified as a defect if its hardness

exceeds 35 HRC, 345 HV10 or 327 HBW, based upon individual indentations. Pipes that contain such

defects shall be treated in accordance with C.3 b) or C.3 c)

9.10.7 Other surface imperfections

 

Other surface imperfections found by visual inspection shall be investigated, classified and treated as

follows.

a) Imperfections that have a depth

0,125 t and do not encroach on the minimum permissible wall

thickness shall be classified as acceptable imperfections and shall be treated in accordance with

Clause C.1.

b) Imperfections that have a depth

> 0,125 t and do not encroach on the minimum permissible wall

thickness shall be classified as defects, and shall be dressed-out by grinding in accordance with

Clause C.2 or shall be treated in accordance with Clause C.3.

c) Imperfections that encroach on the minimum permissible wall thickness shall be classified as defects

and shall be treated in accordance with Clause C.3.

NOTE "Imperfections that encroach on the minimum permissible wall thickness" implies that the portion of the

wall thickness that is beneath the surface imperfection is less than the minimum permissible wall thickness.


 
 
Thanks and Best Regards,
 
G.Murali krishnan
Mob : +966-501487307
Saudi Arabia


On Wed, Mar 19, 2014 at 4:57 PM, Sampath Kumar <skthatham@gmail.com> wrote:
Dear Experts,

We have around 22 CS pipes,[FIRE WATER Line]of size 20"Sch 20 12 mts in length.The pipes are having some manufacturing defect which is running throughn out the pipe.The EPC people wanted to directly accept saying that it will not have any major impact as this is only a fire water line.[It is a pipeline project,construction of Oil storage tanks & Jetty]

Our view is that it can not be a mill scale.If it is a mill scale,it should have gone after the blasting.Other view is it can not  be a rolling defect also.Pitting is ruled out.

Our suggestion to the EPC to do spot blating,If necessary do  grinding,check the thickness and then we will come to conclusion.

Now the question is  Can we reject the total quantity of the pipes on the grounds saying that it has got manufacturing defect.On what basis it can be done.

Why should we accept the pipes?If we have to accept, on what basis.?

What will be the final consequeces If it is accepted directly with out carrying any tests.?

Is there any other way or test we have to do on these pipe.

Pls reply back at your earliest.Kindky give me all the options.

Thanks & Regards
Sampath


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...