WHY PURGE ?

When welding stainless steel, titanium and other corrosion-resistant materials, creating a perfect weld environment is of the utmost importance, because the desired corrosion resistance depends on it. During welding, the heated weld seam is exposed to air and oxidizes if it is not protected. This oxidation must either be prevented or treated later. Successful welding depends in part on a combination of proper purging equipment and techniques, and these are the focus of this article. Preventing Oxidation During the welding of steels, oxidation occurs in the weld seam if oxygen reaches this area unhindered. This situation is even more acute with titanium, zirconium, molybdenum and other gas-reactive metals and alloys. The resulting oxidized surfaces are no longer corrosion-resistant, and further treatment is necessary. Removing oxidation by grinding also removes the metal's passive protection against corrosion. Other mechanical procedures, such as brushing, blasting and pickling remove the oxidation, which restores corrosion resistance. However, in some cases such as pipe welding, removing oxidation after welding is difficult or impossible to do. During pipe welding, oxides are usually located in areas that are almost impossible to access, such as in two 4-inch-diameter pipes that are each 10 feet long. Pickling will restore the corrosion resistance, but it is time-consuming and nearly impossible on a remote job site. Instead of removing oxidation, another solution is to prevent it from occurring in the first place. In essence, this is what purging tries to achieve. With purging, a gas is used to protect the weld seam until it has cooled to the point that oxidation no longer can occur. Usually, an inert gas, such as argon which is heavier than air, is used (see Figure 1). Other purging gases such as nitrogen and nitrogen/hydrogen blends can also be used. Purging Equipment Taping up the ends and purging the whole length of pipe is a common approach, but this time-consuming and uneconomical process usually results in wasted purging gas, unproductive labor time and a less-than-desirable outcome. Proper equipment and accessories should include: 1. A purging unit. 2. Aluminum tape. 3. An oxygen indicator. 4. A tungsten electrode grinder. A purging unit should reduce the purge volume, provide a well-sealed chamber and introduce no contaminants. The purging gas must be distributed at a slow enough speed within the purge chamber so that argon and oxygen mixing is reduced and excess turbulence is minimized-a key to high-quality purging. At the same time, the purging chamber should be sealed against further oxygen penetration. To speed up the purge time, the loss of argon should be reduced and fresh oxygen prevented from entering the weld area. The pipe's joints should be sealed from the outside with a halogen-free, temperature-resistant aluminum tape . Regular tape should not be used for sealing pipe gaps because these adhesives generally contain halogens, specifically chlorine. Chlorine, like hydrogen and oxygen, is absorbed by reactive metals at high temperatures, causing embrittlement in the weld surface. All components used in the manufacture of purging units should therefore be halogen-free, heat-resistant and void of dissimilar metals. An excess pressure vent also should be included to aid in the venting of oxygen and excess purging gas from the purged environment. When welding corrosion-resistant materials and purging, it is important to note that the rest oxygen (the percent volume of oxygen left after purging with an inert gas) is made up of the following: 1. The content in the supplied welding and purging gas. 2. Oxygen penetration and diffusion through internal gas supply lines, gas hoses, seals, connections (including connections within the welding machine), regulators, purging units, and welding gaps. Rest oxygen is composed of many (sometimes small) additions because the final reading at the welding joint can include trace oxygen content in the gas from a small leak at the hose/regulator connection or can enter through the welding gap. Because of this, it is wise to monitor the complete procedure with an oxygen indicator. This sensor should be able to measure accurately to 1 part per million (PPM) oxygen. Oxygen indicators with read-out capabilities of only 0.1 percent (1,000 PPM) or 0.01 percent (100 PPM) may not be accurate enough, as most precision welding is done well below 70 PPM. Higher accuracy makes it possible to find the source of each extra oxygen value and prevents weld failures and/or rework. To ensure optimal weld quality, gas tungsten arc welding (GTAW) electrodes must be ground centrically and longitudinally. The ground tip geometry must be of a high-quality finish to help guarantee proper arc stability. Electrodes that are ground correctly on a tungsten electrode grinder fitted with a diamond wheel last longer and produce better welds because of greater arc penetration. Regrinds should also be done on a tungsten electrode grinder at the same prescribed angle as the welding procedure dictates to maintain consistent parameters and results. Purging Techniques A common question about purging is the flow rate at which the welder should purge. Actually, the flow depends largely on the volume to be purged. In practice, the welder should strive for enough flow to force the oxygen gently out and maintain a slightly higher pressure inside than outside the purge chamber. This action prevents fresh oxygen from re-entering the purged area through the weld seam when welding and, at the same time, minimizes excess turbulence, which can cause instability in the welding arc. The length of purge time is another common question. Besides using practical experience to determine purge time, welders can use many formulas that have been calculated to find the exact moment to weld. However, weld quality depends on many factors, including humidity, volume and material, just to name a few. The correct length of time to typically purge is until the oxygen sensor indicates a value below 70 PPM for stainless steel or below 50 PPM for titanium. This can take between two and four minutes when using a purging unit. Some industries such as semi-conductor, require a level below 10 PPM, and this range may take much longer to reach. The welding parameters should be set by the welding engineer and enforced by quality control. Also, purging should continue until the weld seam has cooled sufficiently so that oxidation can no longer occur. When making multiple root-pass welds, purge gas flow should be maintained until the weld seam is 3/8 to 1/2 inch thick, depending on the specific welding procedure and the material's elasticity. Preheating pipe with high temperatures, as is sometimes recommended, can encourage the formation of chrome oxides, and a rest oxygen content below 100 PPM is highly recommended. The permeability of oxygen gas hoses and supply lines should be monitored closely. Moisture accompanied by oxygen can penetrate gas supply lines and prevent an otherwise clean operation from meeting codes and specifications. This is especially true when the purge gas line has not been used for a while or is being used in a humid environment. In these instances, ensuring adequate gas flow before welding will remove these residual amounts. Weld Quality The effective welding of stainless steel, titanium, nickel, zirconium, molybdenum, tantalum and their alloys for the nuclear, petrochemical, pharmaceutical, semi-conductor, aerospace and food industries requires the proper tools to create a perfect weld environment. Purging equipment and its use can have a major impact on preventing oxidation and improving final weld quality.

For more information, refer to Intercon's website: www.intercononline.com , or give them a call - 1-800-665-6655 A. J. Schenk is V.P. of Sales with Intercon Enterprises Inc. 1125 Fir Ave., Blaine, Wa 98230. Ph: 1-800-665- 6655 Fx: 1-604-946-5340 E-mail: - Website: www.intercononline.com Intercon provides a complete line of GTAW pipe accessories, such as purging equipment, tungsten electrodes and grinders, oxygen indicators, pipe alignment clamps and chains, siIicone rubber plugs and aluminum tape. Dave Dunbar Intercon Enterprises Inc. 1-800-665-6655 8am-4pm Mon.-Fri. (PST)

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...