RE: [MW:13772] Incomplete pen vide B31.3 2004 Ed

My dear, IP is in the root, right? In 8" pipe VT is obviously out ruled. My question is, IP being a serious discontinuity, how is it acceptable even for normal fluid service? IQI contrast - indication density, etc is bit untidy, but the main question is not that. Thanks, SV --- On Tue, 21/2/12, vijayan <vijayan.m@madinagulf.com> wrote: From: vijayan <vijayan.m@madinagulf.com> Subject: RE: [MW:13767] Incomplete pen vide B31.3 2004 Ed To: materials-welding@googlegroups.com Date: Tuesday, 21 February, 2012, 7:00 PM Hi   Ref B31.3   The applicable NDT method for this defect is VT and RT.  If it is an open joint check the depth of IP by visual. But in RT you can approximately identify( Not measure) the depth by difference in contrast relative to the IQI contrast at that location BR M. Vijayan   From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Shashank Vagal Sent: Tuesday, Febru...

RE: [MW:13771] Acceptance Criteria For Chemical Contents Inconel 625 Overlay

Dear Sir,  I fully agree that Inconel 625 (EQNiCrMo3) we can achieve with two layers and Not with single layer of total weld overlay thickness of 7mm By ESSC process with proper magnetic stirring device adjustment  and we can generally get undiluted chemistry at 5-6mm from base line(Particularly of Fe less than 5%   Regards   Hegde P.B. Fabtech Projects and engrs Pune (India) --- On Wed, 22/2/12, Budi Witjaksono <budi.witjaksono@profab-group.com> wrote: From: Budi Witjaksono <budi.witjaksono@profab-group.com> Subject: RE: [MW:13769] Acceptance Criteria For Chemical Contents Inconel 625 Overlay To: "pgoswami" <pgoswami@quickclic.net>, "rinshad abdul rahman" <rinshad043@gmail.com> Cc: materials-welding@googlegroups.com Date: Wednesday, 22 February, 2012, 12:08 PM Dear Mr. Goswami,   Sorry for the late respond due to my current assignment. There is no client specification for this except they only specified inconel 625...

[MW:13769] THK calculation on grid size

Dear Experts, In NPCIL project specification for seamless Alloy steel fittings,following sentence will be given as - Minimum thk will be calculated on grid size minimum 30mm for up to 50NB & 50mm for up to 500NB & 100mm for above size. I never heard about this, I want some information regarding this matter. Kindly share ur thoughts about this topic and give some referances regards, Ankit Khatri -- To post to this group, send email to materials-welding@googlegroups.com To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com For more options, visit this group's bolg at http://materials-welding.blogspot.com/ The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

RE: [MW:13769] Acceptance Criteria For Chemical Contents Inconel 625 Overlay

Dear Mr. Goswami,   Sorry for the late respond due to my current assignment. There is no client specification for this except they only specified inconel 625 overlay 3 mm thickness. We have done experiments with ESSC using single pass (4.5 mm height)  and the 2 layers (9mm height). The following is results at the various location.   Profab 1 st Testing (taken 1.5 mm from the surface) Overlay thickness 4.5 mm Profab 2nd Testing (taken 0.5 mm below surface) Overlay thickness 4.5 mm Profab 3rd Testing (take 4mm below surface Overlay thickness 4.5 mm 0.024 0.022 0.016 0.38 0.32 0.27 0.39 0.33 0.46 19.1 19.3 22.4 56.7 58.6 62.3 7.74 7.86 9.45 2.23 2.12 2.46 12.5 10.4 1.53 0....