If your WPS/PQR states GTAW is qualified up to 8 mm, then the 8.18 mm exceeds the limit. Consult with the
Client and clarify if they will accept the existing WPS with the required adjustments. Otherwise, create a new
WPS that covers GTAW for the thickness of the pipe you are going to use. You cannot use the existing WPS
without modifications due to the thickness exceeding the specified limit.
C Sridhar.
On Mon, 1 Sept 2025 at 16:29, guru <gurupadgs@gmail.com> wrote:
Dear team,--Kindly clarify the problem which is as follows,I have CS wps gtaw+smaw (gtaw upto 8mm thk.)I have to weld 8"seh.40 (8.18mm)CS pipe with full TIG as per client requirement.Can I use the above WPS without SMAW (only GTAW upto 8 mm.thk)Thanks & Regards,