Thursday, April 14, 2011

[MW:10679] GMAW short circuit Welders Qualification

Hi all,

According ASME section IX, in case of welders Qualification of GMAW process - short circuit transfer mode, Radiography is not applicable and we must do Mechanical tests.

Need just to know what's exactly Short circuit transfert mode and how it can defferenciate of others ! by current range ?


Regards.
 

--
زكرياء غراب
GHRAB Zakaria
مسؤول عن الجودة
QA/QC SENAD
مشروع المحطة الحرارية ـ الوحدة الرابعة
المحمدية ـ المغرب

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...