SMAW:
Above Minus 29 Deg C- E7018 ( This electrode is classified for above Minus 29 Deg C, means Mfrs give guarantee of impact property for that temp)
Above Minus 46 Deg C -E7018-1 (This electrode is classified for above Minus 46 Deg C means Mfrs give guarantee of impact property for that temp )
GTAW:
Above Minus 29 Deg C - ER 70 S-3 (This filler will give impact test values at Minus 29 Deg C )
Above Minus 46 Deg C - ER 70 S-6 (This filler will give impact test values at Minus 46 Deg C because it has Managnrse content upto 1.85%
arun
On Sat, Oct 23, 2010 at 12:56 PM, SENTHIL P <senbe381@gmail.com> wrote:
DEARS,
WHAT ELECTRODES USED FOR LOW TEMPERATURE, WHAT IS THE REASON?
EXPECTING URGENT REPLY
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
--
அருணாசலம்
கலைவாணி
சுதர்ஷனா
வருண்
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.