Tuesday, April 25, 2017

Re: [MW:26470] VACUUM TEST FOR SOTRAGE TANKS ROOF AS PER API 650

thank you all

On Fri, Apr 21, 2017 at 2:38 PM, tugrulhan özdemir <tugrulhan9@gmail.com> wrote:
Mr.Pinto,


Please see below


Upon completion, the roof of a tank not designed to be gas-tight, such as a tank with peripheral circulation
vents or a tank with free or open vents, shall receive only visual examination of its weld joints, unless otherwise
specified by the Purchaser.



Note that :  A  bullet  (•)  at  the  beginning  of  a  paragraph  indicates  that  there  is  an  expressed  decision  or  action  required  of  the
Purchaser. The Purchaser's responsibility is not limited to these decisions or actions alone. When such decisions and actions are
taken, they are to be specified in documents such as requisitions, change orders, data sheets, and drawings.



2017-04-13 8:12 GMT+03:00 Pinto Antony <pintoantony81@gmail.com>:
Dear Experts,

we are fabricating a dome roof oil tank with atmospheric venting this vent connected to the flame arrester, in this case, roof air test is required or not???

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/8f9fe7d7-0fdd-447c-81d3-434e99b666e6%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.



--


--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CABSWRjoeS9_vvHG6pz02nJt%2Bi%3DUGyuBViAz9xcDR78_twm8UFw%40mail.gmail.com.

For more options, visit https://groups.google.com/d/optout.



--

Kind Regards

PINTO ANTONY.T

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CALYDc9Pk8_2AP47Z4oiNrFfMUsqUFy4Uy%2BM0eQMOBZu85iN6NA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...