Monday, March 20, 2017

[MW:26234] Regarding Welder Qualification

Dear Experts,

As per ASME Sec IX if for small diameter we have to done qualification e.g. 1/2" dia . Pipe we will have to take multiple specimen to cover the 150 mm length for RT, and also we Can't take specimen more than 4 nos.

I have query which dia we will have to consider for qualification of welder it's Outer dia. Or Inner dia of pipe for circumference length calculation because if we will consider inner dia for calculation then we will have to take more than 4 specimens and which violates the code .

Best Regards,
Mohit Aggarwal

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CALTezPOruStAVdWvREdMUJv4RZQRguYF_9nhW2HM%3DozBKeRhsA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...