Monday, October 10, 2016

Re: [MW:25520] QW 404.12

Hi!
No you can not use this PQR  as AWS/UNS No of each category of SS No and A no as per QW404.37 is essential
Regards
Hegde P.B.


On Sunday, 9 October 2016 7:00 PM, 'prem_nautiyal26' via Materials & Welding <materials-welding@googlegroups.com> wrote:



A WPS/PQR is qualified with ER 316L for corrosion resistant overlay as per ASME SEC IX.
welding process is GTAW.

Can this procedure be used for a welding procedure of ER 310 overlay.

Base material P No. are same.

ASME SEC IX QW 404.12 FOR change in filler metal classification is blank.

Regards

Prem Nautiyal 



Sent from my Samsung Galaxy smartphone.
--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/g4m33nfv05gtdps7ppoc3772.1476006551118%40email.android.com.
For more options, visit https://groups.google.com/d/optout.


No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...