Saturday, October 8, 2016

Re: [MW:25511] Usage of ASME Sec 9 WPS for sub contractor

Hi,

There is no issue if it is agreed in the contract or specified in the scope of work, as longs as the organisation/company who owns the WPS/PQR doesn't have any issues.

Or you may write a new wps based on this project sub-contractor scope and issue to your sub-con with the existing PQR.

regards,
LALU

On Tue, Oct 4, 2016 at 4:46 PM, thulaib arakkal <thulaibwelding@gmail.com> wrote:
Dear All,

We have sub contracted our pipe welding work based on ASME B31.3 and ASME sec IX qualified WPS to another organization. Is it allowed in ASME section IX for a sub contractor to use the main contractor's WPS.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAL2L2JMBzSCg4sYKoc2SsFKSEMEQRi-YwMBpOpAnY%3DQM-gH-JQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAOwU13sidwLUA%2BKKz%2B%2BYWVhz48bD88r_qeSnmW%3DT4bBhH1o5rg%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...