Sunday, September 11, 2016

Re: [MW:25365] WPS requirements according to PQR

Thanks.

I also took the reference of UG-20 but to ensure that more i asked.

Thanks a lot.

Thanks & Regards,

Himanshu panchal


On Sat, Sep 10, 2016 at 7:04 PM, Chandrakant Yadav <yadav.chandrakant@gmail.com> wrote:

Mr Himanshu
Please check the UG 20 for the exception of impact testing. As per your requirement it is must as the mdmt is below -26 deg C


On 10-Sep-2016 7:09 PM, "Himanshu Panchal" <mec4him@gmail.com> wrote:
Dear All,

I want to prepare a WPS for SECVIII Div-1,Material-SA333, MDMT: -46C,Thickness 24 mm.

As per vessel drawing there is no impact test and PWHT requirement.

I have one PQR without impact test.

Can i prepare the WPS based on that PQR who is with out impact test?

MDMT of vessel is -46C.



Thanks & Regards,

Himanshu panchal

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAKHjqA0P6GGCHuozpPeM7P0f5KuaQJhh0CiS1MHYdkrFNqp0Kw%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAAP-FKN_GCq4i3rs-Vu9tXBm7VOEeRDX0zoS8m1YAx_d3j1HaA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAKHjqA3D-GA6-ARh3qSEEuvuk8UpnACSw0SB%2BcPZJ9y%3DnJ7s%3Dg%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...