June has only 30 days not 31. The interpretation is correct.

Rgds
Prakash Gotimukul
AIS, Consultant ASME/ISO/PED/IBR
 Mob:+97152 979 5678

On Tue, Aug 16, 2016 at 11:51 AM, Mhaskar Aly <mhaskar.aly@gmail.com> wrote:

Dear Friends

You might informed about it I am just sharing the information...


Find attached Interpretation regarding Welder continuity as per ASME SEC IX.


What I understood is if a welder is qualified on 1st Jan...his qualification will expire on Jun 31...If suppose this welder has done welding works with this process for first 2 months only (Feb end) & did not weld after that. On June 31st while revalidation of his qualification he will get validity for next two month ie upto August end only not upto Dec 31.

 

Hope to have your understanding.

 

Best regards

 Aly

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAOenW4jcGaQ%2BHz33k5ORKQ2VTjqktRgJZUKLbirevo1zKPnwsA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAOUP4qL5GCR5NuzFAOg%3DyhKHWGWNLybnkYcPdNzvA8%3D5uEOQaQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...