Tuesday, August 23, 2016

[MW:25295] % Ferrite & FN measurements of Duplex Stainless steel welds

Dear Experts,


We have performed qualification on Duplex stainless steel BM UNS 31803 welded to itself with filler ER2594. Shielding gas AR+2% nitrogen


Ferrite measurements of welds were carried out as per ASTM E562 and AWS A4.2.


Client has rejected these values as the correlation is not appropriate.See below reported values and client comment.


From client point of view ,It should have been like VOL % FRRITE = 70% FN VALUE.


Your valuable advise will help us to save this WPS from being rejected.


Many Thanks


Regards,

Mohammed Azharuddin

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAEeeqaKkHHhBuUFxq5QX32g5vOV4JrYdb1X0fWAyf9qSrZHN0w%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...