Thursday, October 3, 2013

RE: [MW:18843] NDT reports review by Level 2 or Level 3-reg

Dear friend,

 

1.       It is totally incorrect that NDT level 3 shall review the NDT reports.

2.       NDT reports can be reviewed by anybody.

3.        NDT results shall be interpreted and evaluated by minimum level 2. NDT can be performed by level 2 or level 1 (provided necessary instruction / direction are given by level 2 or level 3 to level 1 personnel).  In fact, SNT TC 1A permits specific evaluation by level 1 for ‘acceptance / rejection determinations’. But most of the clients and codes don’t permit any evaluation by level 1.

4.       Please refer SNT TC 1A section 4.0 and the written practice for further details.

Thanks,

 

With kind regards,

M. Vedaraju

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Subramaniyan Karunanidhi
Sent: Thursday, October 03, 2013 12:21 PM
To: materials-welding@googlegroups.com
Subject: [MW:18840] NDT reports review by Level 2 or Level 3-reg

 

Hi All,

Is there any code details that NDT reports to be reviewed by NDT level 3?
NDT level 2 can only perform and prepare reports?
Can I find in SNT-TC_!A?
Please reply

Regards,

Karunanidhi

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...