yes, you can


On Wed, Apr 17, 2013 at 7:10 PM, Ezat Adel <ezatadel2008@gmail.com> wrote:
Dear Expert ,

Could you give me your opinion about my supplier send me A350 LF/2 forged flange instead of A 105 N forged flange and i have a WPS for welding A 105 N to API 5l x42 in your opinion this wps will covered  A350 LF/2 to API 5l x42 ?

as i know  A350 LF/2 is a low temp.carbon steel and A 105 N is a carbon steel and both material has the same P no.,Group no. and in my activities i do not need to use a low temp. CS but my question  if i accept this flanges  the wps i have will covered the case.

the WPS i have is E6010 for root pass and E7018 for filling and cap

Thanks in advance

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
 
 

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...