Sunday, April 14, 2013

[MW:17385] E 7018 used instead of E7018-1

Dear Experts,
 
Our welders are used E7018 instead of 7018-1 for A333 Gr-6.
Now client is asking to cut the joints.
Moreover they are asking to prove the remaining joints whether they are welded with 7018-1 or not.
Can anybody suggest a suitable method such as any NDT to prove that ?
So please send your valuable suggestion with reference to code.
 
Thanks & regards,
 
Binu.
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
 
 

No comments:

[MW:34820] RE: 34813] Clarification in Rate of heating and cooling.

Hello,   Please see the response below.   Regards.   P. Goswami, P. Eng, IWE.   From: materials-welding@googlegroups.com <materials-weld...