[MW:16817] Pitting Corrosion Resistance Failure in DSS

Dear Experts,

We are welded DSS A790 UNS S31803 Pipe to pipe PQR welding and we sent it for Mechanical test. But we found PITTING.

The details are below and i attached the test result also.

Material                         :           A 790 UNS S31803 (Pipe to Pipe)

Size                              :           4" X 8.56mm

Filler Used                     :           ER2209 (Metrode) 2.4mm

Max. Interpass               :           Below 50ºC

Max. Heat Input             :           1.2 KJ/MM

Test Method                  :           ASTM 923 Methode C (22ºC – 24HRS)


Now we are planning to do the PQR again. So please give me you idea to avoid the failure again.


Thanks.



--

Regards,

E.Subramanian

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
 
 

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...