Friday, January 25, 2013

Re: [MW:16590] WPS QUALIFICATION WITH CLADDING.

D

-
Dear Hemant 
In your case It is of Tube sheet to shell joint (as per your sketch) Please refer QW 202.4 of ASME sec IX which is self explainatory  and you can qualify PQR accordingly ( In your case it is P43 to P8
Regards
Hegde P.B.

Regards
From: hemant <hsuthar@chemithon.co.in>
Subject: [MW:16585] WPS QUALIFICATION WITH CLADDING.
To: materials-welding@googlegroups.com
Cc: "Hardik Pandya" <hardik_real@yahoo.co.in>, pravin_576@yahoo.co.in
Date: Thursday, 24 January, 2013, 6:52 PM

Dear Sir,

We going to tube to tube sheet joint with as below given material, our tube to joint is groove fillet weld as shown in sketch. I have to qualify WPS for SB 575 to 316L. we have only  SB 575 50mm thick tube sheet material. And 316L plate.

Can I qualify WPS with fillet weld?  Or can I used 316L plate with ERNiCrMo4 cladding and 316L plate for plate to plate qualification.

 

Pls reply.

 

TUBE SHEET- ASTM SB 575, UNS N10276

SHELL-SA 312 TP 316L

 

 

HEMANT SUTHAR

QA/QC

CEPL-SILVASSA

9712973092

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
 
 

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...